J115F1 Series UL Approved, TUV Approved Relay

 

Features

Datasheet in PDF

F Class Insulation Standard
Light Weight and Small Size
Heavy Contact Load
Strong Shock & Vibration Resistance
UL/cUL and TUV Certified

 

Contact Rating NO: 40A@240VAC Resistive
20A@240VAC Resistive 250K cycles
30A@277VAC General Purpose
25A@277VAC Resistive 100K cycles
5A@280VAC Ballast
2hp@250VAC

1hp@125VAC 50K cycles 40C

NC: 30A@240VAC Resistive
20A@240VAC General Purpose
20A@277VAC General Pur

 

Dimensions Contact
Arrangement
Contact Material Coil Voltage Coil Power Contact Resistance
31.7 x 26.9 x 20.3 1A, 1B, 1C AgSnO2, AgSnO2In2O3 5VDC, 9VDC, 12VDC, 24VDC, 48VDC, 110VDC, 12VAC, 24VAC, 110VAC, 120VAC, 220VAC, 240VAC, 277VAC DC: .60W, .90W; AC: 2VA < 30m Ohm

 

 

Insulation Resistance Electrical Life Mechanical Life Dielectric Strength
1000M Ohm @ 500VDC 100K cycles 10M cycles

Contact-to-Contact: 1500V rms

Contact-to-Coil: 4000V rms, 2500V rms

 

 

Operating Temperature Mounting Methods Agency Approvals
-55C to 125C PC Pin UL E197852 & TUV

 

 

Dimensional Drawing


 

Schematic


 

PC Board Layout